Last updated: 2026-10-05 05:50 (UTC)
Phone/tablet as BYOD (Bring Your Own Device) HMI/SCADA in a local network

Communication over Wi-Fi between a mobile device running HMI Droid and the PLC can be established either directly (e.g., via Modbus/TCP or Siemens S7 Communication) or through a serial port via a port server (e.g., using COMLI or Modbus RTU).
The connection type should be set to TCP/IP, or to UDP/IP when using SattBus COMLI.
HMI Droid can be used, for example, with Wi-Fi PLCs from XLogic Sweden (select the Modbus/TCP class 1 protocol).
The MOXA NPort 5110 is a port server that has been tested with HMI Droid and works well.
Phone/tablet as BYOD (Bring Your Own Device) HMI/SCADA over mobile internet

Communication over mobile internet between a device with HMI Droid and the PLC either directly (eg Modbus/TCP or Siemens S7 Communication) or through a serial port via a port server (eg COMLI or Modbus RTU).
Connection type should be set to TCP/IP, or UDP/IP when using SattBus COMLI.
Router configured for "port forwarding".
If the IP address on the Internet is not fixed, you can use a dyn-dns service.
HMI Droid can be used e.g. with WiFi PLCs from XLogic Sweden. (Select protocol Modbus/TCP class 1.)
Port server tested with HMI Droid and works well is MOXA NPort 5110.
Using a VPN tunnel is recommended. Many routers and NAS devices have built-in VPN servers that are easy to setup.
Phone/tablet as BYOD (Bring Your Own Device) HMI/SCADA over Internet behind Carrier-grade NAT

Communication over Internet between a device with HMI Droid/Odrid HMI and a PLC behind Carrier-grade NAT either directly (eg Modbus/TCP or Siemens S7 Communication) or through a serial port via a port server (eg COMLI or Modbus RTU).
Connection type should be set to TCP/IP, or UDP/IP when using SattBus COMLI.
NOTE: Since there is no public IP-address to connect to, a service like e.g. ZeroTier is required.
HMI Droid can be used e.g. with WiFi PLCs from XLogic Sweden. (Select protocol Modbus/TCP class 1.)
Port server tested with HMI Droid and works well is MOXA NPort 5110.
Odrid HMI on a Mac in a local network

Requirements: macOS 10.15 or later.
Communication over Ethernet between a Mac and the PLC either directly (eg Modbus/TCP or Siemens S7 Communication) or through a serial port via a port server (eg COMLI or Modbus RTU).
Connection type should normally be set to TCP/IP.
Odrid HMI can be used e.g. with WiFi PLCs from XLogic Sweden. (Select protocol Modbus/TCP class 1.)
Port server tested with Odrid HMI and works well is MOXA NPort 5110.
Panel-PC, ODROID or Raspberry Pi in a local network

Communication over ethernet between panel PC, ODROID or Raspberry Pi with HMI Droid and the PLC either directly (eg Modbus/TCP or Siemens S7 Communication) or through a serial port via a port server (eg COMLI or Modbus RTU).
Connection type should be set to TCP/IP, or UDP/IP when using SattBus COMLI.
HMI Droid can be used e.g. with WiFi PLCs from XLogic Sweden. (Select protocol Modbus/TCP class 1.)
Port server tested with HMI Droid and works well is MOXA NPort 5110.
Media player or PC with Android-x86 in a local network

Communication over ethernet between a media player or a PC with HMI Droid and the PLC either directly (eg Modbus/TCP or Siemens S7 Communication) or through a serial port via a port server (eg COMLI or Modbus RTU).
Connection type should be set to TCP/IP, or UDP/IP when using SattBus COMLI.
HMI Droid can be used e.g. with WiFi PLCs from XLogic Sweden. (Select protocol Modbus/TCP class 1.)
Port server tested with HMI Droid and works well is MOXA NPort 5110.
Phone/tablet as BYOD (Bring Your Own Device) HMI/SCADA over Bluetooth Classic or Bluetooth LE
Examples of Bluetooth adapters that have been tested with HMI Droid:
- DSD TECH SH-B20
- IOGEAR GBC232A
- Sena Parani-SD1000
- Microchip BM77 (BT v3.0)
- JY-MCU BT_BOARD V1.05 / HC-06
- JDY-23 (with HMI Droid 1.7.8.158)
Note: Bluetooth SPP is not supported in the iOS version of the app.
Example of Bluetooth LE adapters that has been tested with Odrid HMI (iOS/macOS):
- Microchip BM77
- Microchip BM78
- JDY-33
Bluetooth® brands and logotype are registered trademarks of Bluetooth SIG, Inc.
S7 and STEP 7 are trademarks of Siemens AG.