Get it on Google Play           Available at Amazon           Download on the App Store           Get

Last updated: 2024-02-10 06:50 (UTC)

Phone/tablet as BYOD (Bring Your Own Device) HMI/SCADA in a local network

HMI android wi-fi wifi plc phone tablet touch smartphone pad modbus/tcp rtu LAN BYOD Bring Your Own Device

Communication over Wi-Fi between a mobile device with HMI Droid and the PLC either directly (eg Modbus/TCP or Siemens S7 Communication) or through a serial port via a port server (eg COMLI or Modbus RTU).

Connection type should be set to Wi-Fi, or Ethernet UDP when using SattBus COMLI.

HMI Droid can be used e.g. with WiFi PLCs from XLogic Sweden. (Select protocol Modbus/TCP class 1.)

Port server tested with HMI Droid and works well is MOXA NPort 5110.


Phone/tablet as BYOD (Bring Your Own Device) HMI/SCADA over mobile internet

HMI android wi-fi wifi plc phone tablet smartphone pad touch modbus/tcp rtu mobile internet BYOD Bring Your Own Device

Communication over mobile internet between a device with HMI Droid and the PLC either directly (eg Modbus/TCP or Siemens S7 Communication) or through a serial port via a port server (eg COMLI or Modbus RTU).

Connection type should be set to Wi-Fi, or Ethernet UDP when SattBus COMLI, no matter how Android device connects to the internet.

Router configured for "port forwarding".

If the IP address on the Internet is not fixed, you can use a dyn-dns service.

HMI Droid can be used e.g. with WiFi PLCs from XLogic Sweden. (Select protocol Modbus/TCP class 1.)

Port server tested with HMI Droid and works well is MOXA NPort 5110.

Using a VPN tunnel is recommended. Many routers and NAS devices have built-in VPN servers that are easy to setup.


Phone/tablet as BYOD (Bring Your Own Device) HMI/SCADA over Internet behind Carrier-grade NAT

HMI android wi-fi wifi plc phone tablet smartphone pad touch modbus/tcp rtu mobile internet BYOD Bring Your Own Device

Communication over Internet between a device with HMI Droid/Odrid HMI and a PLC behind Carrier-grade NAT either directly (eg Modbus/TCP or Siemens S7 Communication) or through a serial port via a port server (eg COMLI or Modbus RTU).

Connection type should be set to Wi-Fi, or Ethernet UDP when SattBus COMLI, no matter how Android device connects to the internet.

NOTE: Since there is no public IP-address to connect to, a service like e.g. ZeroTier is required.

HMI Droid can be used e.g. with WiFi PLCs from XLogic Sweden. (Select protocol Modbus/TCP class 1.)

Port server tested with HMI Droid and works well is MOXA NPort 5110.


Odrid HMI on a Mac in a local network

Odrid HMI MacOS wi-fi wifi plc modbus/tcp rtu LAN

Requirements: macOS 10.15 or later.

Communication over Ethernet between a Mac and the PLC either directly (eg Modbus/TCP or Siemens S7 Communication) or through a serial port via a port server (eg COMLI or Modbus RTU).

Connection type should normally be set to Wi-Fi.

Odrid HMI can be used e.g. with WiFi PLCs from XLogic Sweden. (Select protocol Modbus/TCP class 1.)

Port server tested with Odrid HMI and works well is MOXA NPort 5110.


Panel-PC, ODROID or Raspberry Pi in a local network

HMI android wi-fi wifi plc phone tablet touch smartphone modbus/tcp rtu LAN panel-pc

Communication over ethernet between panel PC, ODROID or Raspberry Pi with HMI Droid and the PLC either directly (eg Modbus/TCP or Siemens S7 Communication) or through a serial port via a port server (eg COMLI or Modbus RTU).

Connection type should be set to Wi-Fi, or Ethernet UDP when using SattBus COMLI.

HMI Droid can be used e.g. with WiFi PLCs from XLogic Sweden. (Select protocol Modbus/TCP class 1.)

Port server tested with HMI Droid and works well is MOXA NPort 5110.


Media player or PC with Android-x86 in a local network

HMI android wi-fi wifi plc pjone tablet touch smartphone pad modbus/tcp rtu LAN media player

Communication over ethernet between a media player or a PC with HMI Droid and the PLC either directly (eg Modbus/TCP or Siemens S7 Communication) or through a serial port via a port server (eg COMLI or Modbus RTU).

Connection type should be set to Wi-Fi, or Ethernet UDP when using SattBus COMLI.

HMI Droid can be used e.g. with WiFi PLCs from XLogic Sweden. (Select protocol Modbus/TCP class 1.)

Port server tested with HMI Droid and works well is MOXA NPort 5110.


Phone/tablet as BYOD (Bring Your Own Device) HMI/SCADA over Bluetooth Classic or Bluetooth LE

HMI android wi-fi wifi plc phone tablet touch smartphone pad bluetooth BYOD Bring Your Own Device

Example of Bluetooth adapters that has been tested with HMI Droid:

Note: There is no support for Bluetooth SPP in the iOS-version of HMI Droid.



Example of Bluetooth LE adapters that has been tested with Odrid HMI (iOS/macOS):

Bluetooth® brands and logotype are registered trademarks of Bluetooth SIG, Inc.